1. In the initial stage of operation, check the anchor bolts at least once a day to prevent loosening.
2. Shaker shall be equipped with electrical protection device.
3. When the rotating direction of the motor does not meet the requirements, the phase sequence of the power supply can be adjusted.
4. The motor should ensure good lubrication. Lithium-based grease (ZL-3) should be added once every two weeks. When refueling, a proper amount of lithium-based grease should be added through the oil cup. When sealed bearings are used, the motor is not equipped with oil cups.
5. After 1500 hours of running, the bearing should be checked and replaced immediately if there is serious damage.
6. When the machine is used again after a long time of shutdown, the insulation resistance should be measured. It should be used for measuring 500 V megohm meters, which should be greater than 0.5 megohm.